18529092692

Home >> News
News
Huawei OSN3500 devices configure SDH services to report AU_AIS alarms
| 2025-11-21|Back

OSN3500 causes the SEP1 veneer to constantly report AU_AIS alarms due to the mismatch between the J1 and C2 overhead bytes of the docking device, so you need to pay attention to the consistency of the overhead byte settings when docking.

Impact on the system

ThisalarmcausesAU-3 service interruption.

Possible Causes

The upstream site received MS_AIS, R_LOS, R_LOF, B2_EXC, AU_AIS, and B3_EXC alarms.

1. the opposite end station sends a partial fault.

2. This station receives partial failure.

3. Failure of the cross-board of the opposite end station.

Related Products

OptiX OSN 3500

OptiX OSN 3500 II

Failure Category

  • Device docking failure
  • AU_AIS

Phenomenon Description

After the OptiX OSN 3500 device is configured with a SEP1 single board and docked with data devices from other vendors, AU-AIS alarms are constantly reported.

Cause Analysis

1. For NG-SDH equipment, the alarm of the standby time slot is not detected in the pass-through state, which is inconvenient for fault localization, and if service interruption occurs after the inversion, it is necessary to loop back to locate the faulty site.

2, in the normal state, if you need to detect whether the standby time slot is normal, you can configure the service that passes through and hang up the table to test, for the standby time slot configured with the service, NG-SDH detects the alarm.

3, although under normal circumstances METRO5000, OCS and NG-SDH equipment group multiplexing section of the ring network is not a problem, but the special circumstances of the subtle differences as maintenance engineers should also know.

Operation Steps

  1. Login to T2000 and select "Network Element Manager".
  2. Select SEP1 board in the board tree, and select "Configuration > Overhead Management > VC3 Channel Overhead" in the function tree.
  3. Select the "Tracking Byte J1" and "Signal Flag C2" tabs, respectively, and check the J1 and C2 overhead bytes sent by the docking device, and find that they do not match the default values of Huawei devices. After resetting the overhead bytes to make them consistent, the AU-AIS alarm disappeared.

The technical information in this chapter and the related SDH equipment troubleshooting procedures are provided by Shenzhen Optical Transmission Network Technology Co. Huawei SDH optical transmission equipment, SDH transmission equipment sales phone: 13430988088 Welcome to call!


Sales OSN3500_Product Quotation_Sales Manufacturer_Product Characteristics_Product Description_Huawei SDH transmission equipment sales
Supply OSN3500_Troubleshooting_Installation and testing_Technical indicators_Technical parameters_Huawei SDH transmission equipment sales

Contact Us
Name:Mr Zhang
Phone:18529092692
Tel:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Contact
18529092692
Phone:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Follow Us
Otrans Technology is a high-tech enterprise deeply engaged in optical transmission and network communication equipment, specializing in...
Copyright © 2025 Otrans all right reserve XML 网站模板