Protection requirements

SSN4GSCC single board is the intelligent system control board, cooperating with the network management system to manage the single boards of the equipment, realizing the mutual communication between the equipment, the single board can be inserted in the OSN3500 subrack slot 17, slot 18. slot 18 is the main board slot by default, and slot 17 is the backup board slot.
Products
Huawei SDH Transmission Equipment OSN3500 GSCC Main Control Board Technical Parameters

OSN3500 SSN4GSCC Functions and Features
The GSCC single board supports functions and features such as master control, official business, communications, and system power monitoring.
The specific functions and features of the GSCC single board are shown in Table 1.
Table 1 Functions and features of GSCC single board
OSN3500 SSN4GSCC alarm indicators
The indicators on the OSN3500 SSN4GSCC single board panel are:
Single-board hardware status lamp (STAT)-red and green indicator lamps
Single-board primary and backup status lights (ACT)-green light
Single-board software status light (PROG) - red and green dual-color light
Service warning indicator (SRV) - red, green and yellow color indicators
A-way-48V power supply indicator (PWRA) - red, green bi-color indicator
Road B - 48V power supply indicator (PWRB) - red and green dual-color indicators
System +3.3V backup power indicator (PWRC) - red and green bicolor indicators
Alarm Loss Mask (ALMC) - yellow light
See Indicators for specific meanings of the single board indicators.
OSN3500 SSN4GSCC Single Board Interface
There is no interface on the panel of the GSCC board, the interface it provides is led through the AUX board For detailed description, please refer to the interface description of the AUX.
The N4GSCC/N6GSCC single board panel has one soft reset switch and one alarm cutout switch, the type and purpose of the switches are shown in Table 1.
Table 1 GSCC Single Board Switch Descriptions
| Switch Name | Switch Type | Purpose |
|---|---|---|
| RESET | Soft reset switch | Pressing this switch softly resets the main control unit. |
| ALM CUT | Alarm cutout switch | Short press the switch to cut out the current alarm sound. Press and hold the switch for 3 seconds to permanently cut out the alarm sound, and press and hold the switch again to cancel the alarm cut function. |